• JJZ-FF架空就地型翻牌故指 45度图
  • JJZ-FF架空就地型翻牌故指 正视图
  • JJZ-FF架空就地型翻牌故指 组合
  • JJZ-FF架空就地型翻牌故指 组合2
  • JJZ-FF架空就地型翻牌故指
JJZ-FF Overhead Line Fault Indicator
JJZ-FF Overhead Line Fault Indicator is usually used in 5~38KV overhead line power distribution network to monitor and detect short-circuit and earth fault. The fault is indicated by mechanical flag and three ultra-bright blinking LEDs with 360º sight. The indicator can be mounted under live conditions with the help of an adapter and a hot stick.
  JJZ-FF Overhead Line Fault Indicator is usually used in 5~38KV overhead line power distribution network to monitor and detect short-circuit and earth fault. The fault is indicated by mechanical flag and three ultra-bright blinking LEDs with 360º sight.The indicator can be mounted under live conditions with the help of an adapter and a hot stick. The trip current and reset time can be set by dial switches during production. And battery low voltage warning can be distinguished and indicated by red mechanical flag.
 

 
Features
 
Short circuit Fault:Red mechanical flag and three red ultra-bright blinking LEDs.
Earth-fault:Red mechanical flag and three red ultra-bright blinking LEDs
 
Low Battery Warning: Red mechanical flag.
Parameter Adjust:The parameters can be adjusted by dial switches during production.
 
Power Supply:Lithium battery, type AA 2.7Ah/3.6V.
 
 
 
 
parameter
Subject Value
Short-circuit Trip Current (Phase to Phase) 150A, 300A, 450A, 600A, can be set by dial switch during production
Trip Current Delay 40, 80, 120, 200ms, can be set during production
Indication Unit Reset
  1. Manual by magnet
  2. Time reset: adjustable, 2 minutes, 8h, 24h, 48h, can be set during production
  3. Auto reset after repower, 30s default, only for permanent fault
Protection Class IP68
Internal Type Test According to IEEE495-2007
Operation
Temperature Range
-40~+70℃
Power Supply Lithium battery type AA 3.6V/2.7Ah, replaceable
Battery Life  10 years
Weight Approx. 600g
Dimensions Diameter: 93mm
Height: 128mm
 
Accuracy
0A~300A ±3A
300A~800A ±1%
Cable Diameter
Ranges
6mm~42mm
Blinking Frequency 10 per minute, adjustable
Max. load/fault Current 1100A
Voltage range 5~14KV. For higher voltage, can be customized
Current withstand 31.5KA/4s

 
Related Products
  • JYZ-HW V2.0 Overhead Line Remote Fault Indicator
  • Transient Recording Type Fault Indicator
  • Handheld Remote Fault Reader
  • JYL-FF Remote Overhead Line Wave Recording Fault circuit Indicator
  • JJZ-FF Overhead Line Fault Indicator
 
Related Solutions
  • Four-faith overhead fault indicator positioning system
Trial Sample
Chat Oneline
Technical Support